  • 1.75吨-16.6吨 Specifications: 1.75 tons-16.6 tons
  • 92% Thermal efficiency: 92%
  • 燃油、气、甲醇 Applicable fuel: fuel oil, gas, methanol
  • 化工、油脂、石化、纺织、印染、塑料、橡胶、纤维、碳素、建筑 Applications: chemical, oil, petrochemical, textile, printing and dyeing, plastics, rubber, fiber, carbon, construction

YY(Q)W系列燃油(气)导热有炉以油(气)为燃料,以导热油为介质,利用热油轮回油泵强制介质进行液相轮回,将热能输送给用热设备后再返回导热油炉重新加热,从而实现了在低压力下获得高工作温度介质的功能,并且能对介质运行进 Product introduction: YY (Q) W series fuel oil (gas) heat-conducting furnace uses oil (gas) as fuel and heat-conducting oil as medium. It uses a hot oil tank oil return pump to force the medium to perform liquid-phase circulation. It then returns to the heat-conducting oil furnace to reheat, so that the function of obtaining a medium with a high working temperature under low pressure is achieved, and the medium can be run into the medium.

24-hour service hotline: 15896709659 (Manager Dong)

Product introduction Working principle Performance advantage Technical parameters

product description

微信图片_20190703165309.jpg微信图片_20190703165351.jpg

YY (Q) W series fuel (gas) heat-conducting furnace uses oil (gas) as fuel and heat-conducting oil as medium. It uses a hot oil tank oil return pump to force the medium to perform liquid-phase recirculation. The heat energy is transferred to the heat equipment and then returned to heat conduction The oil furnace is reheated, so that the function of obtaining a medium with high working temperature under low pressure is realized, and the operation of the medium can be controlled with high precision. And because the boiler module can be installed as a whole, it is convenient to operate and maintain, and it is an ideal heating equipment with safety, high efficiency and energy saving. The combustion oil (gas) has a high-temperature flame generated after the burner enters the inner coil to form a radiant heating surface. After passing through the inner part of the furnace tube, it rotates 180 ° forward to enter the interlayer area of the inner tube, middle tube and outer tube to form a convection heating surface. . Then in the upper part of the mezzanine, it enters the second mezzanine area of the middle and outer pipes, and finally it is discharged into the atmosphere through the chimney at the rear of the second mezzanine area.

working principle

y1.png

Performance advantage

1. Liquid-phase circulating heating, no heat loss due to condensate discharge, and high thermal efficiency of the heating system.

2. Obtain low-pressure and high-temperature heat medium with uniform heating and convenient adjustment, which can meet the requirements of precise process temperature.

3, the working medium is heated and exothermic and the temperature changes the volume change, there are compensation technical measures in the system.

4. Prior to circulating heating, there are technical measures to strictly control the air, moisture and other low volatile matter content in the working medium.

5. Large-diameter combustion chamber: The boiler combustion chamber is composed of large-diameter coils, with sufficient fuel combustion space, complete combustion, and high thermal efficiency.

6. Coil design: The spiral coils inside and outside the furnace are made of multiple-head, small-diameter steel pipes. The coils have good thermal expansion performance, low stress, and are safe and reliable.

7. Process design: three-way smoke, the medium flows through the inner and outer coils, the flow rate is uniform, and the operation is safe and stable.

8. Sufficient output: The heating surface is reasonably arranged, the area is large, the heat transfer effect is good, the efficiency is high, and the output is stable and sufficient.

9, the unique sealing of the smoke box: the furnace cover adopts the overall structure, multi-stage labyrinth seal, special sealing technology and materials, good compressibility, completely block the leakage of smoke, and can be reused.

10. Perfect automatic control measures: (1) accurately control the oil temperature; (2) set multiple control protections for medium temperature, pressure and super smoke, etc. to ensure safe and reliable operation.

11, leading level of automatic control: the boiler controller uses Siemens / Delixi electrical components, reliable performance. Realize man-machine dialogue and remote control functions.

Technical Parameters

Data model parameters YY (Q) W-300Y (Q) (25) YY (Q) W-350Y (Q) (35) YY (Q) W-600Y (Q) (50) YY (Q) W-900Y (Q) (75) YY (Q) W-1200Y (Q) (100) YY (Q) W-1500Y (Q) (125) YY (Q) W-1800Y (Q) (150) YY (Q) W-2400Y (Q) (200) YY (Q) W-3000Y (Q) (250) YY (Q) W-3500Y (Q) (300) YY (Q) W-4000Y (Q) (350) YY (Q) W-4600Y (Q) (400) YY (Q) W-6000Y (Q) (500) YY (Q) W-7100Y (Q) (600)
Rated thermal power (KW) 300 350 600 900 1200 1500 1800 2400 3000 3500 4000 4600 6000 7100
Thermal efficiency(%) > 90
Design working pressure (MPa) 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.1 1.1 1.1
Medium temperature (℃) 320
Furnace oil content (m3) 0.21 0.25 0.28 0.44 0.7 1.0 1.48 2.2 3.5 4.7 5.7 7.2 8.5 9.5
Amount of circulating oil (m3 / h) 40 40 60 80 100 100 150 200 200 250 250 250 300 300
Piping connection diameter (DN) 100 100 100 100 125 125 125 150 150 200 200 200 250 250
Complete system installed capacity (KW) 17 17 27 40 40 42 45 70 70 85 85 85 100 100
Overall dimensions (mm) A 1016 1016 1216 1416 1716 1716 2000 2000 2320 2500 2520 3080 3220 3400
L1 2050 2350 3050 3290 3300 3900 4400 5100 5300 6000 6200 6400 8000 8400
L2 2650 3000 3550 3800 4065 4665 4900 5900 6200 6900 7200 7400 9000 9400
L3 300 300 250 250 300 300 350 350 350 400 400 450 450 450
L4 500 500 350 370 600 620 400 650 700 700 700 750 750 750
H1 900 900 900 1000 1350 1350 1500 1500 1700 1700 1700 1800 2000 2400 2600
H2 750 750 920 1010 1100 1100 1200 1300 1450 1450 1550 1760 1800 1852
H3 700 700 820 930 1100 1050 1250 1200 1400 1400 1500 1700 1800 1900
H4 650 650 810 900 950 950 1100 1100 1300 1300 1400 1600 1800 1890
Total equipment weight (Kg) 1750 1950 3580 4290 4900 5450 6550 11400 14600 16600 25000 28200 30760 35340
Basic size (mm) 890 1190 1750 1770 2000 2470 2620 3700 3900 4600 4820 5000 6600 7000
1150 1450 2000 2100 2300 2750 3450 4000 4200 4900 5100 5300 6900 7300
700 700 720 880 1150 1150 1120 1300 1500 1500 1600 1800 2200 2400
1100 1100 900 1100 1550 1510 1600 1700 1900 1900 2000 2200 2600 2500