Vertical gas-conducting oil furnace

  • 10万大卡-120万大卡 Specifications: 100,000 kcal-1.2 million kcal
  • 93% Thermal efficiency: 93%
  • 天然气柴油液化气甲醇 Applicable fuel: natural gas diesel liquefied gas methanol
  • 纺织、印染、塑料、橡胶、食品加工、木材加工、沥青加热、纸箱生产 Applications: textiles, printing and dyeing, plastics, rubber, food processing, wood processing, asphalt heating, carton production

恒安立式燃气导热油炉,由较先进的程序控制器控制,能实现正常燃烧所必需的各种功能,能在正常状态、事故状态及非常情况下,自动实施保护性报警,配以相应的液位控制器、压力控制器、温度控制器,实现进出口压力指示、进出口温度指示,保证热载体温度在正常范围内波动,压力在允许压力波动范围内。 Product introduction: Heng'an vertical gas heat-conducting oil furnace is controlled by a more advanced program controller, which can realize various functions necessary for normal combustion. It can automatically implement protective alarms in normal conditions, accident conditions and extraordinary circumstances. With the corresponding liquid level controller, pressure controller and temperature controller, the inlet and outlet pressure indication and inlet and outlet temperature indication are realized to ensure that the temperature of the heat carrier fluctuates within the normal range and the pressure is within the allowable pressure fluctuation range.

24-hour service hotline: 15896709659 (Manager Dong)

Product introduction Working principle Performance advantage Technical parameters

product description

Heng'an vertical gas heat-conducting oil furnace is a new type of special boiler with low-pressure and high-temperature working characteristics. Its heating temperature can reach 340 ° C in liquid phase or 400 ° C in vapor phase. Organic heat carriers can be used for heating in various production situations where uniform and stable heating is not allowed, and the direct heating of the flame is not allowed for the heating temperature between 150 ° C and 380 ° C. The fuel (gas) organic heat carrier furnace uses oil (gas) as the fuel and heat-conducting oil as the medium. The medium is circulated through the medium using a hot oil circulating oil pump. The heat energy is transferred to the heating equipment and then returned to the heating furnace for reheating. Obtain high working temperature under low pressure, and can perform high-precision control work on media operation. The system has a high heat utilization rate. Due to the overall installation of the module, it is easy to operate and maintain. It is an ideal heating equipment that is safe, efficient and energy-saving. The fuel oil (gas) is ignited by the high-temperature flame generated by the burner into the inner coil to form a radiant heating surface, which is rotated 180 ° forward through the rear of the inner coil to enter the interlayer area of the inner, middle and outer tubes to form a convection heating surface. Then in the upper part of the mezzanine, it enters the second mezzanine area of the middle and outer coils, and at the rear of the second mezzanine area, it is discharged into the atmosphere to the chimney.

working principle

The gas-conducting heat-conducting oil furnace is controlled by a more advanced program controller, which can realize various functions necessary for normal combustion. It can automatically implement protective alarms in normal conditions, accident conditions and extraordinary circumstances, with corresponding liquid levels. The controller, pressure controller, and temperature controller realize the inlet and outlet pressure instructions and inlet and outlet temperature instructions to ensure that the temperature of the heat carrier fluctuates within the normal range and the pressure is within the allowable pressure fluctuation range.

Performance advantage

(1) Obtain low-pressure and high-temperature heat medium, easy to adjust, uniform heat supply, and can meet the precise process temperature. (2) Liquid-phase circulating heating, no heat loss due to condensation and discharge, and high thermal efficiency of the heating system. (3), the working medium is heated and exothermic and the temperature changes the volume change, there are compensation technical measures in the system. (4) Prior to circulating heating, there are technical measures to strictly control the air, moisture and other low volatile matter content in the working medium.

Technical Parameters